RTMED Polyester
- Tissue reaction:Small
- Product color:Green/blue/black
- Sterilization method:Sterilizing epoxy ethane
- Product packaging:Single – supported aluminum foil bag
- Commodity number:1/2,3/8,1/4,3/4,5/8
- Description
Description
RTMED Polyester Surgical Suture is an FDA-cleared, sterile, non-absorbable, synthetic braided multifilament suture composed of high-molecular-weight Polyethylene Terephthalate (PET). Precision-braided and uniformly coated with medical-grade silicone or PTFE to minimize tissue drag and capillarity, RTMED Polyester delivers indefinite tensile strength retention, superior knot stability, and exceptional fatigue resistance for cardiovascular, orthopedic, and general surgical procedures across Pakistan.
ISO 13485:2016 Certified
CE Mark Approved
DRAP Registered (Form-5A / Class IIb)
EO Sterile Packaging
Technical Specifications & Polyester Material Properties
| Product Line | RTMED Polyester Braided Non-Absorbable Suture |
| Chemical Formulation | Linear Polyethylene Terephthalate (PET) polymer fibers |
| Filament Construction | Tight micro-braided multifilament (high flexibility and handling pliability) |
| Surface Coating | Medical Grade Silicone / PTFE (ensures smooth tissue passage and eliminates sawing effect) |
| Color Options | Green (D&C Green No. 6) or White / Undyed |
| Tensile Retention Profile | Permanent / Indefinite (not subject to enzymatic degradation or weakening over time) |
| USP Range | USP 6-0 to USP 5 (EP 0.7 to EP 7.0) |
| Needle Metallurgy | AISI 300 series siliconized surgical stainless steel (high bend resistance) |
| Needle Types | Taper Point (Round Bodied), Reverse Cutting, Double-Armed Cardiovascular (with or without PTFE pledgets) |
| Regulatory Standards | US FDA 510(k) Cleared, CE Marked, ISO 13485:2016, DRAP Registered (Class IIb) |
Available Polyester Suture Gauges & Clinical Applications
| USP Gauge | Suture Length | Needle Configuration | Primary Surgical Speciality |
|---|---|---|---|
| USP 2-0 & 3-0 | 75 cm / 90 cm | Double-Armed Taper Point (with PTFE pledgets) | Cardiac Valve Replacement & Annuloplasty Rings |
| USP 1 & 2 | 75 cm / 100 cm | Heavy Round Bodied / Cutting (35 mm – 45 mm) | Orthopedic Surgery (Rotator Cuff, Tendon & Ligament Repair) |
| USP 4-0 & 5-0 | 45 cm / 75 cm | Taper Point / Reverse Cutting (16 mm – 20 mm) | Ophthalmic (Scleral Buckling) & Vascular Surgery |
| USP 5 | 75 cm / 100 cm | Heavy Blunt Point / Cutting Needles | Cervical Cerclage (Shirodkar / McDonald Procedure) |
Clinical Benefits of Polyester in Surgery
- Indefinite Tensile Retention: Synthetic PET fibers will not degrade, providing lifelong structural holding for critical prosthetic implants and valve rings.
- Exceptional Knot Security: Braided multifilament construction eliminates knot slip while resisting dynamic repetitive mechanical loads.
- Atraumatic Smooth Coating: Medical-grade coating minimizes tissue friction, preventing the cheese-wiring effect common in uncoated braids.
- Biological Inertness: Causes minimal acute inflammatory reaction followed by complete fibroblastic encapsulation.
For synthetic monofilament permanent vascular anastomoses, explore our RTMED Polypropylene Sutures.
Surgical Handling & Knot Technique for Polyester Sutures
Due to its braided multifilament core and high tensile properties, RTMED Polyester suture offers exceptional handling characteristics and reliable tactile feedback during knot seating. Unlike monofilament alternatives that can suffer from spring-back memory, braided polyester adapts smoothly under the surgeon’s fingers and holds firmly under repetitive pulsatile cardiovascular stresses. This makes RTMED Polyester the suture of choice for prosthetic cardiac heart valve attachments, rotator cuff tendon anchorings, and heavy orthopedic soft tissue fixations in surgical centers across Pakistan.
Frequently Asked Questions on Polyester Suture Procurement
Q1: Are RTMED Polyester sutures US FDA approved?
Yes. RTMED non-absorbable Polyester braided sutures hold US FDA 510(k) clearance, CE marking, and ISO 13485:2016 certification, and are registered with the Drug Regulatory Authority of Pakistan (DRAP) under Class IIb medical device regulations.
Q2: Are RTMED Polyester sutures available with PTFE pledgets?
Yes. For cardiac surgery and valve reconstruction procedures, polyester sutures can be supplied in double-armed needle configurations pre-loaded with medical-grade PTFE felt pledgets to prevent suture pull-through in friable tissue.
Q3: How are these sutures packaged for hospital stock?
Supplied in boxes of 12 or 36 individually hermetically sealed, sterile foil packs with high barrier integrity to ensure sterility and prevent contamination.
Tender & Wholesale Hospital Supply:
M. Islam & Sons supplies provincial cardiology institutes, orthopedic departments, and teaching hospitals across Pakistan. Inquire with our institutional procurement desk for tender rates, Free Sale Certificates, and batch delivery schedules.